30.6.4  LVD circuit characteristics 
 
LVD Detection Voltage of Reset Mode and Interrupt Mode 
(T
A
 = 
40 to +105°C, V
PDR
 
 V
DD
 
 3.6 V, V
SS
 = 0 V) 
Parameter Symbol  Conditions 
MIN. 
TYP. 
MAX.
Unit 
Power supply rise time 
3.01 
3.13 
3.25 
V
LVD2
 
Power supply fall time 
2.94 
3.06 
3.18 
Power supply rise time 
2.90 
3.02 
3.14 
V
LVD3
 
Power supply fall time 
2.85 
2.96 
3.07 
Power supply rise time 
2.81 
2.92 
3.03 
V
LVD4
 
Power supply fall time 
2.75 
2.86 
2.97 
Power supply rise time 
2.70 
2.81 
2.92 
V
LVD5
 
Power supply fall time 
2.64 
2.75 
2.86 
Power supply rise time 
2.61 
2.71 
2.81 
V
LVD6
 
Power supply fall time 
2.55 
2.65 
2.75 
Power supply rise time 
2.51 
2.61 
2.71 
Detection 
voltage 
Supply voltage level 
V
LVD7
 
Power supply fall time 
2.45 
2.55 
2.65 
Minimum pulse width 
t
LW
 
 300 
 
 
μs 
Detection delay time 
 
  
 
300 
μs 
 
Remark  V
LVD (n
−1)
 > V
LVDn
: n = 3 to 7 
 
LVD Detection Voltage of Interrupt & Reset Mode 
(T
A
 = 
40 to +105°C, V
PDR
 
 V
DD
 
 3.6 V, V
SS
 = 0 V) 
Parameter Symbol 
Conditions 
MIN. 
TYP. 
MAX.
Unit 
V
LVD5
 
VPOC2, VPOC1, VPOC0 = 0, 1, 1, falling reset voltage 
2.64 
2.75 
2.86 
Rising release reset voltage
2.81 
2.92 
3.03 
V
LVD4
 
LVIS1, LVIS0 = 1, 0
Falling interrupt voltage 
2.75 
2.86 
2.97 
Rising release reset voltage
2.90 
3.02 
3.14 
Interrupt & reset 
mode 
V
LVD3
 
 
LVIS1, LVIS0 = 0, 1
Falling interrupt voltage 
2.85 
2.96 
3.07 
 
Caution  Set the detection voltage (V
LVD
) to be within the operating voltage range.  The operating voltage range 
depends on the setting of the user option byte (000C2H/010C2H).  The following shows the operating 
voltage range. 
 
HS (high-speed main) mode:  V
DD
 = 2.7 to 3.6 V@1 MHz to 32 MHz 
 
V
DD
 = 2.4 to 3.6 V@1 MHz to 16 MHz 
 
30.6.5  Supply voltage rise slope characteristics 
 
(T
A
 = 
40 to +105°C, V
SS
 = 0 V) 
Parameter Symbol
Conditions 
MIN. 
TYP. 
MAX.
Unit 
Supply voltage rise 
SV
DD
  
 
 
54  V/ms 
 
Caution  Be sure to maintain the internal reset state until V
DD
 reaches the operating voltage range specified in 
30.4  AC Characteristics, by using the LVD circuit or external reset pin.