Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
APPENDIX  A   REVISION  HISTORY 
(9/11) 
Page Description 
Classification
p.739 
Modification of Figure 18-5.  When the Interrupt Request Signal is Generated in the 
SNOOZE Mod and Figure 18-6.  When the Interrupt Request Signal is not Generated in 
the SNOOZE Mode 
(c) 
CHAPTER 19  RESET FUNCTION 
p.740 Modification 
of CHAPTER 19  RESET FUNCTION (c) 
p.742, 743 
Modification of figure, Note, and Caution in Figure 19-2.  Timing of Reset by RESET Input 
and Figure 19-3.  Timing of Reset Due to Execution of Illegal Instruction, Watchdog 
Timer Overflow, RAM Parity Error, or Illegal Memory Access Overflow 
(c) 
p.744 
Modification of description and Note in Table 19-1.  States of Operation During Reset 
Period 
(c) 
p.746 Modification 
of 
Figure 19-4.  Format of Reset Control Flag Register (RESF)  (c) 
p.747 Modification 
of 
Table 19-3.  RESF Register Status When Reset Request Is Generated (c) 
p.748 Modification 
of 
Figure 19-5.  Procedure for Checking Reset Source (c) 
CHAPTER 20  POWER-ON-RESET CIRCUIT 
p.749 Modification 
of 
20.1  Functions of Power-on-reset Circuit (c) 
p.751 to 753 
Modification of Figure 20-2.  Timing of Generation of Internal Reset Signal by Power-on-
reset Circuit and Voltage Detector 
(c) 
CHAPTER 21  VOLTAGE DETECTOR 
p.754 Modification 
of 
21.1  Functions of Voltage Detector (c) 
p.755 Modification 
of 
Figure 21-1.  Block Diagram of Voltage Detector (c) 
p.756 Modification 
of 
Figure 21-2.  Format of Voltage Detection Register (LVIM) (c) 
p.757 
Modification of Note and Caution in Figure 21-3.  Format of Voltage Detection Level Select 
Register (LVIS) 
(c) 
p.758, 759 
Modification of Table 21-1.  Format of User Option Byte (000C1H/010C1H)  (c) 
p.760 Modification 
of 
21.4.1  When used as reset mode (c) 
p.761 
Modification of Figure 21-4.  Timing of Voltage Detector Internal Reset Signal Generation 
(Option Byte LVIMDS1, LVIMDS0 = 1, 1) 
(c) 
p.762 Modification 
of 
21.4.2  When used as interrupt mode  (c) 
p.763 
Modification of Figure 21-5.  Timing of Voltage Detector Internal Interrupt Signal 
Generation (Option Byte LVIMDS1, LVIMDS0 = 0, 1) 
(c) 
p.764 Modification 
of 
21.4.3  When used as interrupt & reset mode (c) 
p.765, 767 
Modification of Figure 21-6.  Timing of Voltage Detector Reset Signal and Interrupt Signal 
Generation (Option Byte LVIMDS1, LVIMDS0 = 1, 0) 
(c) 
p.768 Modification 
of 
Figure 21-7.  Processing Procedure After an Interrupt Is Generated (c) 
p.769 Modification 
of 
Figure 21-8.  Initial Setting of Interrupt and Reset Mode (c) 
p.770, 771 
Modification of (1)(2), and (3) in 21.5  Cautions for Voltage Detector (c) 
CHAPTER 22  SAFETY FUNCTIONS 
p.772 Modification 
of 
(6)  Frequency detection function (c) 
p.775 
Modification of Figure 22-3.  Flowchart of Flash Memory CRC Operation Function (High-
speed CRC) 
(c) 
p.779, 780 
Modification of Figures 22-8 and 22-9  (c) 
p.782 Modification 
of 
Figure 22-11.  Invalid Access Detection Area  (c) 
Remark  “Classification” in the above table classifies revisions as follows. 
 
(a): Error correction, (b): Addition/change of specifications, (c): Addition/change of description or note,  
(d): Addition/change of package, part number, or management division, (e): Addition/change of related 
documents 
R01UH0305EJ0200  Rev.2.00 
 
 
966  