ICOM IC-706MKIIG User Manual

Page of 75
45
6
REMOTE JACK (CI-V) INFORMATION
CONTROLLER TO IC-706MKIIG
FE FE 58 E0 Cn Sc
Data area
FD
Preamble code (fixed)
Transceiver’s default address
Controller’s default address
Command number
(see table at right)
Sub command number
(see table at right)
BCD code data for frequency or
memory number entry
End of message code (fixed)
OK MESSAGE TO CONTROLLER
FE FE 58 E0 FB FD
Preamble code (fixed)
Transceiver’s default address
Controller’s default address
OK code (fixed)
End of message code (fixed)
NG MESSAGE TO CONTROLLER
FE FE 58 E0 FA FD
Preamble code (fixed)
Transceiver’s default address
Controller’s default address
NG code (fixed)
End of message code (fixed)
IC-706MKIIG TO CONTROLLER 
FE FE E0 58 Cn Sc
Data area
FD
Preamble code (fixed)
Controller’s default address
Transceiver’s default address
Command number
(see table at right)
Sub command number
(see table at right)
BCD code data for frequency or
memory number entry
End of message code (fixed)
CI-V connection example
The transceiver can be connected through an option-
al CT-17 
CI
-
V LEVEL CONVERTER
to a personal comput-
er equipped with an RS-232C port. The Icom
Communication interface-V (CI-V) controls the follow-
ing functions of the transceiver.
Up to four Icom CI-V transceivers or receivers can be
connected to a personal computer equipped with an
RS-232C port. See p. 55 for setting the CI-V condition
using initial set mode.
Data format
The CI-V system can be operated using the following
data formats. Data formats differ according to com-
mand numbers. A data area is added for some com-
mands.
Personal
computer
IC-706MKIIG
CT-17
9–15 V DC