ICOM IC-706MKIIG User Manual

Page of 75
46
6
REMOTE JACK (CI-V) INFORMATION
*
1
When wide or normal operation is available, add “00” for wide oper-
ation or “01” for normal operation; when normal or narrow operation
is available, add “00” for normal operation or “01” for narrow opera-
tion; when wide, normal and narrow operation is available, add “00”
for wide operation, “01” for normal operation and “02” for narrow
operation.
*
2
Memory channel number 1A=0100/1b=0101, 2A=0102/2b=0103,
3A=0104/3b=0105, C1=0106, C2=0107.
COMMAND TABLE
Cn
Sc
Description
00
Send frequency data
01
xx
Send mode data
02
Read band edge frequencies
03
Read display frequency
04
Read display mode
05
Set frequency data
00*
1
Set LSB
01*
1
Set USB
02*
1
Set AM
06
03*
1
Set CW
04*
1
Set RTTY
05*
1
Set FM
06*
1
Set WFM
Set to VFO
00
Set to VFO A
07
01
Set to VFO B
A0
VFO A=B
B0
Switch VFO A and B
08
Set to memory mode
mc*
2
Mch
09
Memory write
0A
Memory to VFO
0B
Memory clear
0C
Read duplex offset frequency
0D
Set duplex offset frequency
Cn
Sc
Description
0E
00
Scan stop
01
Scan start
00
Split OFF
01
Split ON
0F
10
Simplex mode
11
Duplex mode
12
Duplex + mode
00
10 Hz TS
01
100 Hz TS
02
1 kHz TS
03
5 kHz TS
04
9 kHz TS
10
05
10 kHz TS
06
12.5 kHz TS
07
20 kHz TS
08
25 kHz TS
09
100 kHz TS
11
xx
ATT ON/OFF; 00=OFF; 20=ON
15
01
Read squelch condition
02
Read S-meter level
02
Preamp setting
12
AGC setting
16
22
NB setting
42
TONE setting
43
TSQL setting
44
COMP setting
46
VOX setting
47
BK-IN setting
19
00
Read transceiver ID code