5.1 Drive 
Error 
The drive functionality in case of an error is determined using the following objects: 
6007h:  defined according to the 
SimplIQ
 CANopen Implementation Manual.
 
603Fh:  reflects the 16 lower bits of object 0x1003, which, together with this object, get the 
emergency value regardless of the emergency message mask in object 2F21h. 
Object 0x6007: Abort connection option code 
This object details the motor control behavior after a heartbeat failure. It has no effect if 
the motor is already off. 
 
Object description:
 
Index 6007h 
Name 
Abort connection option code 
Object code 
VAR 
Data type 
INTEGER16 
Category Optional 
 
Entry description:
 
Access Read/Write 
PDO mapping 
No 
Value range 
-32,768…32,767 
Default value 
 
Data description:
 
(Command details are found in 
SimplIQ
 Command Reference Manual.
Option 
Code 
 
Meaning 
 
Details 
0 No 
action 
 
Malfunction 
Motor is off (MO=0) and motor failure code is 
0x800. The failure is reported and possibly 
activates an AUTOERR routine similar to 
other failures (MF command). 
2 Device 
control 
command 
“Disable_voltage” 
Motor is off (MO=0), but no failure indication 
is set (MF=0). 
3 Device 
control 
command “Quick_stop” 
ST command is executed. Its action depends 
on unit mode (UM). 
 
CANopen DSP 402 Implementation Guide 
 
MAN-CAN402IG (Ver. 1.2) 
 
 