32 
 
Data description: 
Value Description 
-32,768…-1 Manufacturer 
specific 
Disable drive function 
Slow down on slow-down ramp and then disable the drive 
Slow down on quick-stop ramp and then disable the drive 
Slow down on current limit and than disable the drive (tq 
mode only)  
4 Not 
supported 
Slow down on slow-down ramp and stay in QUICK STOP 
Slow down on the current limit and stay in QUICK STOP 
(tq mode only) 
8 Not 
supported 
9…32,767 Reserved 
  An attempt to set an unsupported value causes the transmission of abort code 
0609 0030: Value exceeded. 
Object 0x605B: Shutdown option code  
This parameter determines which action should be taken in case of the transition: 
OPERATION ENABLE => READY TO SWITCH ON. 
 
Object description: 
Index 605Bh 
Name 
Shutdown option code 
Object code 
VAR 
Data type 
INTEGER16 
Category Optional 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
INTEGER16 
Default value