Communication Manager Maintenance-Object Repair Procedures
1048 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Use list measurements ds1 summary to show the length of time the test ran (Test 
Duration field) and number of bit errors detected (Loopback/Span Test Bit-Error 
Count field).
Use release board to restore the trunks or ports on the TN767E DS1 Interface circuit pack to 
the in-service state.
Table 360: Test #1216 End Loopback/Span Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry test ds1-loop location end-loopback/span-test 
at 1-minute intervals up to 5 times.
1005
ABRT
End Loopback/Span test cannot be executed in the current configuration. 
To run this, the TN767E (or higher-suffixed) DS1 must be administered 
for 24-channel operation. The Bit Rate field on the DS1 circuit pack 
administration screen must be set to “1.544” for 24-channel operation.
1015
ABRT
Ports on the DS1 Interface circuit pack have not been busied out to 
out-of-service.
1. Enter busyout board location to put all trunks or ports of the 
DS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
ABRT
Internal system error
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 3