DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
1051
 
Table 361: Test #1227 ICSU Status LEDs Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
The ICSU Status LEDs test cannot be executed for the current configuration. 
The test applies only to TN767E or later DS1 circuit packs administered for 
24-channel (1.544-Mbps) operation.
2. If the circuit pack is a TN767E (or higher-suffixed) DS1 circuit pack, 
then retry the command.
1951
ABRT
The ICSU Status LEDs test cannot be executed because a 120A1 (or 
higher-suffixed) CSU module or a 401A (or higher-suffixed) T1 sync splitter 
is not physically installed. If using a 120A1 CSU module/T1 sync splitter, 
physically connect it to the TN767E board on the back of the port carrier. 
Otherwise, ignore this abort.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command.
PASS
The ICSU Status LEDs test executed successfully. A PASS result, however, 
does not necessarily mean that the status LEDs behaved properly. It only 
means that the software successfully attempted to light the status LEDs. 
This is a visual test. The service technician must visually exam the behavior 
of the LEDs while the test is running. The LEDs are functioning properly if 
the four status LEDs are lit red for 5 seconds, then lit green for 5 seconds, 
then lit yellow for 5 seconds. If the LEDs behave differently, escalate this 
problem.