Avaya 03-300430 User Manual

Page of 2574
DS1C-BD
Issue 1 June 2005
1085
 
Replacing a DS1 Converter Circuit Pack with 
the Same Type DS1 Converter Circuit Pack
Duplicated
PNC
!
WARNING:
WARNING:
On a system with duplicated PNC, synchronization may be provided over a 
combination of active and standby components. This condition is indicated by an 
OFF-BOARD WRN alarm against TDM-CLK with Error Type #2305. Repairs to 
standby PNC in this state may disrupt service. Otherwise, if the active PNC is 
functional, replacement of a standby component will not disrupt service.
!
WARNING:
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.
Steps
Comments
Enter status pnc.
Verify that the component to be replaced is on the 
standby PNC.
Enter busyout pnc.
Enter busyout board location.
location represents the cabinet-carrier-slot address 
of the circuit pack to be replaced.
Replace the circuit pack with the same 
DS1 converter board type.
Enter release board location.
CAUTION: Do not busyout any Expansion 
Interface circuit pack after this point.
Enter test alarms long clear for 
category exp-intf.
Wait 5 minutes for SNI-BD, SNI-PEER, 
FIBER-LK, and DS1C-BD alarms to 
clear, or enter clear 
firmware-counters <a-pnc or 
b-pnc>.
Use the letter designation of the pnc that holds the 
replaced component (the standby pnc).
Enter status pnc.
If either PNC’s state of health is not “functional”, 
consult the PNC-DUP section of the Maintenance 
Manual.
Enter release pnc.