Communication Manager Maintenance-Object Repair Procedures
1106 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Every part of this test is executed under firmware control and the result is sent back to the 
maintenance software. The test is executed by sending digital data through every DS1 facility 
channel. Two different test patterns are used, these are hexadecimal values 55 and AA.
For a standard-, duplex-, or high-reliability system (no PNC duplication), this test can only be 
executed at the endpoint that is closer to the media server relative to the neighbor DS1 
converter circuit pack because of its impacts on the system control links, also the completion of 
the test will be delayed in this configuration to wait for the recovery of the system control links. 
For a critical-reliability system (PNC duplication), the test can be executed at any DS1 converter 
circuit pack.
Figure 59: Far-End Lightwave Transceiver Loop-Back Test
Table 376: Test #789 Far-End FOT (Lightwave Transceiver) Loop-Back Test 
Error 
Code
Test 
Result
Description / Recommendation
1410
ABRT
The test aborted because no lightwave transceiver is present. The neighbor 
DS1 converter circuit pack and the fiber endpoint are connected via metallic 
cable. This abort may be ignored.
2000
ABRT
Timed out while waiting for a response from the circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
 1 of 3
lightwave
transceiver
SNI
B
DS1CONV
DS1CONV
Test starts here
A
EI Network
Loops here
Metallic or Fiber Connection
Fiber Connection