Communication Manager Maintenance-Object Repair Procedures
1222 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Expansion Interface Packet Interface Test (#589)
This test is nondestructive. This test attempts to send a data packet from the TN1655 Packet 
Interface circuit pack through any intervening EI circuit packs and/or SNI circuit packs and 
through the EI circuit pack to be tested. The path the data packet takes is dependent on the 
location of the EI circuit pack to be tested and whether the system has duplicated PNC. The 
following diagrams and short discussion of each describe the different paths the test uses.
Figure 71: Expansion Interface Packet Interface Test—Packet Endpoint Loop
The path shown in 
on page 1222 is used when testing a PN EI that is on the active PNC.
0
NO 
BOARD
No board was detected by the test.
1. Resolve either wrong board (error 125) or no board (error 131) issues.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity (error 1538). If hyperactive, use reset board 
location
.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 415: Test #336 Expansion Interface Reset Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
(Optional)
CSS
EXP-INTF EXP-INTF
Packet Bus (PPN) 
Packet Bus (PN X)
PKT-
INT
LAPD
ENDPT