Table 416: Test #589 Expansion Interface Packet Interface Test 
Error 
Code
Test 
Result
Description / Recommendation
1033
ABRT
The test cannot run because the EI circuit pack does not have a fiber link 
administered to it and there is not sufficient data to run the test or because 
EI circuit packs on other port networks needed for this test are out of 
service.
1. Execute list fiber-link and determine whether the EI circuit pack 
under test is an endpoint of one of the administered fiber links. If so, 
then proceed to step 2. If not, then this is considered to be a spare 
board, and the test should not be attempted on this EI circuit pack.
2. Follow procedures for applicable configuration:
Direct Connect:
1. Use list config for the cabinet and carrier where the neighbor EI 
circuit pack resides. If the results reveal that the board is not 
recognized by software, the board is out of service because of this 
condition. Perform the following steps:
a. If this test is being executed on an EI circuit pack located in the PN, 
enter display errors and resolve any EXP-PN errors for the port 
network where the neighbor EI circuit pack resides. Re-execute this 
test.
b. If this test continues to abort with this abort code reset the DS1 
converter circuit pack (if so equipped) or the neighbor EI circuit pack. 
This will not be destructive since the circuit pack cannot be serving 
as the Expansion Archangel if it is not in service.
2. Run Test #237 and check for EXP-INTF circuit pack Error Type 1281 in 
the Error Log. If Error Type 1281 is present and/or Test #237 does not 
pass, see repair procedures for Test #237, in 
3. If Test #237 passes, reseat the EI circuit pack. This will not be 
destructive since the circuit pack cannot be serving as the Expansion 
Archangel if it is not in service.
4. Repeat Test #237.
 1 of 5