Avaya 03-300430 User Manual

Page of 2574
EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1227
 
1139
ABRT
The packet bus in the PN where this EI circuit pack resides has a major 
alarm against it. This test needs to use the alarmed port network’s packet 
bus.
1. Enter display alarms and resolve any PKT-BUS alarms.
2. Retry the command.
1141
ABRT
The Packet Interface circuit pack is out of service.
1. See 
on page 1799 for the recommended 
repair procedure.
1144
ABRT
The PN’s packet bus has a major alarm against it. This test needs to use 
the alarmed PN’s packet bus.
1. Enter display alarms and resolve any PKT-BUS alarms.
2. Retry the command.
1394
ABRT
The EI circuit pack is out of service and the test cannot be run. This 
condition is due to a change in the EI circuit pack’s ability to communicate 
with the EI or SNI circuit pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF Error Type 1281. 
If Error Type 1281 is present or if Test #237 does not pass, see the 
repair procedures for Test #237, in 
2. If Test #237 passes, rest the EI pack. Note that this will not be 
destructive to the port network where EI circuit pack resides because it 
will not be serving as the expansion Archangel if it is not in service.
3. Repeat this test. 
1395
ABRT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC 
and duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, use change 
system-parameters duplication to enable PNC.
2. Use set pnc lock to prevent the system from doing a PNC 
interchange.
3. Repeat this test.
Table 416: Test #589 Expansion Interface Packet Interface Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 5