Communication Manager Maintenance-Object Repair Procedures
1234 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
5016 
5017 
5018 
5019 
5032 
5033 
5048 
5064 
5080 
5096 
5112
FAIL
Initialization failure: the EI circuit pack reset successfully and restarted 
execution, but the EI circuit pack detected communication errors during 
hardware initialization. The nature of the failure may prevent the EI circuit 
pack from communicating with its neighbor EI circuit pack on the opposite 
end of the fiber. The fault itself may be either on the EI circuit pack or on 
the lightwave transceiver.
1. If every other test on this EI circuit pack is passing and no other errors 
have been logged against this circuit pack, replacement of the 
lightwave transceiver or the circuit pack is recommended, but not 
critical.
2. If some tests on this EI circuit pack are failing or other errors have been 
logged against this circuit pack, replace the lightwave transceiver and/
or the EI circuit pack.
PASS
The EI was successfully reset, and it restarted execution. It also passed all 
of its initialization tests and detected a lightwave transceiver. Remove the 
EI circuit pack from the busyout state by using release board PCSS.
1. Execute test board PCSS short. Refer to errors for each test.
0
NO 
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity (Error 1538). If hyperactive, use reset board 
location
.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace 
the board and retest.
Table 417: Test #224 Expansion Interface Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 5 of 5