Expansion Interface Fiber Out-of-Frame (FOOF) Query Test (#238)
This test is nondestructive.
This test is a request to an EI circuit pack to determine whether it is currently detecting the 
framing sequence on the incoming fiber’s data stream. If it cannot detect this framing signal, the 
EI circuit pack will not be able to establish a link with the opposite EI or SNI circuit pack.
For EI-to-EI fiber links, this test is run on both EI circuit pack endpoints of the fiber link.
Table 437: Test #238 Expansion Interface Fiber Out-of-Frame Query Test
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error (software).
1. Run test board location separately for each EI endpoint on this 
fiber link and follow the procedures for this test in the 
maintenance manual.
2. If the test continues to abort or fail, escalate the problem.
1033
ABRT
The EI circuit pack does not have a fiber link administered to it. There is not 
sufficient data to run test. Because test fiber-link was run, the 
expansion interface should be administered on a fiber link, therefore this 
must be a software problem.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Run test board location separately for each EI endpoint on this 
fiber link and follow the procedures in 
2100
ABRT
System resources required to run this test are not available.
1. Run test board location separately for each EI endpoint on this 
fiber link and follow the procedures in 
2500
ABRT
Internal system error
1. Run test board location separately for each EI endpoint on this 
fiber link and follow the procedures in 