Avaya 03-300430 User Manual
FIBER-LK (Fiber Link)
Issue 1 June 2005
1279
207
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped
SNI in slot 7. Use list fiber-link to see a fiber link’s endpoints.
SNI in slot 7. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the
in
in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1281, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1281, replace
the SNI in slot 7.
208
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped
SNI in slot 8. Use list fiber-link to see a fiber link’s endpoints.
SNI in slot 8. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the
in
in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1537, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1537, replace
the SNI in slot 8.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
15 of 22