207
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped 
SNI in slot 7. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1281, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1281, replace 
the SNI in slot 7.
208
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped 
SNI in slot 8. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1537, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1537, replace 
the SNI in slot 8.
Table 440: Test #759 Configuration Audit  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 15 of 22