Avaya 03-300430 User Manual

Page of 2574
HYB-LINE (Hybrid Line)
Issue 1 June 2005
1339
 
1392
ABRT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port (the port is 
a TTI port) or list config (the display shows a t for the port).
2. If list config or display port indicate that the port is not a TTI 
port, escalate the problem. If both commands indicate that the port is a 
TTI port, the abort is correct, and no action is necessary.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
The system could not allocate a tone generator for the test.
1. Resolve any TONE-PT errors.
2. If no TONE-PT errors appear in the Error Log, retry the test at 1-minute 
intervals up to 5 times.
2103
ABRT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed. User may be able to use conference circuit without 
difficulty in some cases. In other extreme cases, conference calling will be 
totally restricted.
The failure may be due to off-board circumstances, the most common of 
which is an off-hook occurring during the test. Also, check the error logs 
against the GPTD-BD, the TONE-BD, and the TONE-PT.
1. This error can be caused by a disconnected terminal. First, ensure that 
the terminal is connected and the wiring is OK.
2. Then, enter display port and status station to determine 
whether the station is idle. If so, enter test port for this port.
3. If test continues to fail, enter busyout port and release port, and 
then retest the port.
4. It is possible that the port may still be functional from a user's point of 
view.
Table 467: Test #57 Hybrid Circuit and Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4