Avaya 03-300430 User Manual
IPMEDPRO (TN2302 IP Media Processor)
Issue 1 June 2005
1371
An audio channel using G.711 is setup between both boards. A 1004-Hz test tone is transmitted
from the source PN to the destination PN over the G.711 audio channel. The test tone is then
transmitted from the destination PN to the source PN.
from the source PN to the destination PN over the G.711 audio channel. The test tone is then
transmitted from the destination PN to the source PN.
Table 482: Short IP 2-Way Transmission Test (#1505)
Error
Code
Code
Test
Result
Result
Description / Recommendation
1002
ABRT
The system could not allocate timeslots for the test. The system may be
under heavy traffic conditions or it may have timeslots out of service due
to TDM-BUS errors.
under heavy traffic conditions or it may have timeslots out of service due
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
2. If system has TDM-BUS errors, clear any errors, and retry the
command at 1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
1003
ABRT
The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors. Even without TTR-LEV errors, a Tone
Detector could be unavailable in the PN containing the circuit pack
being tested. Verify that at least one Tone Detector resides in this
PN. If not, this test always aborts, but does not harm the system.
being tested. Verify that at least one Tone Detector resides in this
PN. If not, this test always aborts, but does not harm the system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals
up to 3 times.
1014
ABRT
Board not inserted.
2000
ABRT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2012
ABRT
Generic system call failed. Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1 of 3