Communication Manager Maintenance-Object Repair Procedures
1370 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Short IP 2-Way Transmission Test (#1505)
This test is nondestructive.
This test attempts to verify IP network connectivity between one pair of IP Media Processors 
that are connected to a customer’s LAN/WAN IP network.
This test creates a G.711 audio path between the source IP Media Processor board specified in 
the command line and a destination IP Media Processor board. The destination media 
processor board is chosen by the system. The destination media processor is chosen from a 
port network other than the port network containing the source media processor. In addition, the 
destination media processor board is chosen from the same IP network region as the source 
media processor board or is chosen from an IP network region that is administered to be 
connected to the IP network region of the source media processor board.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the 
IPMEDPRO interface if it is not already administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseat the board to reinitialize it.
3. If the board was found to be correctly inserted in step 1, then enter 
busyout board location.
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 481: Test #1406 MP Diagnostic Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3