Avaya 03-300430 User Manual

Page of 2574
ISDN-SGR (ISDN-PRI Signaling Group)
Issue 1 June 2005
1431
 
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: this switch sent a message to the far-end switch or terminal adapter, and the 
far end did not respond in the allotted time. Possible causes include link failure and 
congestion or outage at the far end. The Aux Data field contains layer-3 protocol information 
used by internal counters.
If no other symptoms are present, no action is required. If layer-3 communication is down, 
there should be indications in the screen of alarms and errors for link components. Check 
for other errors against ISDN-SGR, ISDN-TRK, and other hardware components on the link.
There is no test to clear these errors. The error counter is decremented by 1 every 15 
minutes.
c. Error Type 257: the primary signaling channel connection has been lost for more than 90 
seconds. If a secondary signaling channel does not exist or is not in service, the associated 
B channels will be placed in the ISDN Maintenance/Far-End state. The B channels will not 
be usable for outgoing calls, although incoming calls will still be accepted. The switch will 
automatically attempt to recover the signaling link. Pay particular attention to the results of 
Test #636 (Primary Signaling Link Hardware Check) in the test sequence. When the link 
769
Any
Primary Signaling 
Link Hardware 
Check (#636)
test signaling-group grp#
1025
Any
Secondary 
Signaling Link 
Hardware Check 
(#639)
test signaling-group grp#
1793 (
Any
Layer 2 Status 
Test (#647)
WRN
OFF
test signaling-group grp#
2049 (
Any
Layer 2 Status 
Test (#647)
WRN
OFF
test signaling-group grp#
2305 (
Any
Remote Layer 3 
Query (#637)
MIN
OFF
test signaling-group grp#
3585 (
Port 
number
None
3842 –
3942 (
Port 
number
None
Table 514: ISDN-PRI Signaling Group Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2