MAINT (PN’s Maintenance Circuit Pack)
Issue 1 June 2005
1499
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2033
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2034
ABRT
Background maintenance on the PN’s Maintenance circuit pack is 
running the Serial Channel Local Loop-around test.
1. Wait 30 seconds, and retry the test up to 5 times.
22901
ABRT
Test disabled via software patch. 
FAIL
The on-board circuitry associated with the standby serial link is defective. 
Since the PN’s Maintenance circuit pack reported this failure, the 
on-board circuitry associated with the active serial link is functional.
1. This test checks the circuitry on the PN’s Maintenance circuit pack 
associated with the standby Expansion Interface link.
a. In a switch without duplicated Port Network Connectivity (PNC), 
current service will not be affected because the circuitry failing is 
not being used. Nevertheless, a Minor alarm will remain in the 
Alarm Log against MAINT. Therefore, the PN’s Maintenance 
circuit pack must be replaced.
b. In a switch with duplicated PNC, service is not affected as long as 
you do not interchange the PNCs. Otherwise, the connection to 
the PN’s Maintenance circuit pack will be lost. Losing this 
connection would mean losing connectivity to the terminal and PN 
Environment maintenance. The PN’s Maintenance circuit pack 
must be replaced to correct this problem.
Table 538: Test #229 Serial Channel Local Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3