Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1514 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Support for Laptop PCs
S8700 | 8710
 / 
S8500
Field technicians can access the TN802 circuit pack through:
pcAnywhere client software
A directly-connected keyboard, monitor, and mouse
pcANYWHERE Client Software
1. Attach a male-to-male serial cable and a NULL modem connector (if not built into the 
cable you use) to the COM2 connector (Note 8 in 
on page 1515). Attach the other end to the serial port of your laptop.
2. Launch the pcANYWHERE application.
3. Click on Add Remote Control Item.
4. In the Properties window, choose the communication port to which you connected the 
cable in Step 1.
IML DWN #
Internal error on the IP Trunk. System shuts down and sends an error 
message to the board.
MSHUT #, 
where both 
MSHUT and 
# are blinking
The system is in the process of shutting down due to a front panel button 
press. Do not attempt to remove board.
MSHUT #, 
where # is 
blinking
The system has shut down gracefully.
Table 547: TN802 LCD messages for IP trunks  (continued)
Display
Explanation
 2 of 2