Avaya 03-300430 User Manual

Page of 2574
MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 June 2005
1533
 
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be initiated by a 
system technician-demanded reset board location.
Table 554: Test #53 SAKI Sanity Test 
Error
Code
Test
Result
Description / Recommendation
None
ABRT
System resources required for this test are not available.
1. Retry reset board at 1-minute intervals up to 5 times.
1015
ABRT
Port is not out-of-service.
1. Busyout the circuit pack (busyout board location).
2. Execute reset board.
2100
ABRT
System resources required for this test are not available.
1. Retry reset board at 1-minute intervals up to 5 times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute reset board.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the short test sequence.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Use add ds1 
location to administer the MAPD interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log 
to determine whether the board is hyperactive. If so, the board was 
shut down. Reseating the board re-initializes it.
3. If the board was inserted correctly, enter busyout board.
4. Enter the reset board command.
5. Enter the release board command.
6. Enter the test board long command.
This should re-establish the linkage between the internal ID and the port.