Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1538 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Use add ds1 
location to administer the MAPD interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log 
to determine whether the board is hyperactive. If so, the board was 
shut down. Reseating the board re-initializes it.
3. If the board was found to be inserted correctly, enter busyout 
board.
4. Enter the reset board command.
5. Enter the release board command.
6. Enter the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 563: Test #146 Translation Update Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2