Avaya 03-300430 User Manual

Page of 2574
MEDPROPT (TN802/TN2302/TN2602 MED PRO DSP PORT)
Issue 1 June 2005
1559
 
DSP Port Status Query Test (#1407)
This test is nondestructive.
This test queries the state of the DSP port.
Table 575: DSP Port Status Query Test (#1407) 
Error
Code
Test
Result
Description / Recommendation
1
ABRT
This port is Out of service (OOS) due to:
A board-level problem, for example no IP address has been 
translated for this location.
A DSP hardware problem (see 
2
ABRT
This port has been made maintenance busy.
1002
ABRT
The system could not allocate timeslots for the test. The system may be 
under heavy traffic conditions, or it may have timeslots out of service 
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, retry the command at 1-minute intervals up to 3 times.
2. If the system has TDM-BUS errors, clear any errors, and retry the 
command at 1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
2000
ABRT
 Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
Unable to get status for this port. Verify that this board has been 
administered correctly, and that there are no alarms against this board.
PASS
The board is functioning properly and the port is in-service and available.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) 
issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity (Error 1538). If hyperactive, use reset board 
location
.
3. Run the test again. If it fails, replace the board and retest.