Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1578 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
PASS
Hybrid Line Station audits passed.
1. Although this test will never actually return a FAIL result except for 
the Internal system error described above, it is possible that it will 
enter Error Type 257 or 513 into the Error Log. To determine whether 
there are any problems that don’t show up in the test result, look for 
these error types in the Error Log.
2. If these errors appear in the Error Log, or if user complaints persist, 
investigate by using other circuit pack tests, and by examining the 
station, wiring, and connections.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout 
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. 
If this is not the case, check to ensure that there is a valid board inserted.
Table 583: Test #61 MET Line Station Audits Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2