Avaya 03-300430 User Manual

Page of 2574
MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1609
 
 
FAIL
MM710 detects a Loss of Signal alarm. The physical link is broken or 
the remote DS1 endpoint is down. All trunks or ports of this MM710 are 
out-of-service. 
1. Check the physical connection of the MM710 Interface Media 
Module and the cable.
2. Check the physical connection of the MM710 Interface Media 
Module to the terminating device. 
3. Check premise distribution system (or intra-premise wiring) for 
physical connection failures.
4. If the MM710 connects to a T1 network facility, call the vendor of the 
T1 carrier to diagnose the remote DS1 endpoint. 
5. If the MM710 Interface Media Module connects directly to a switch, 
call the system technician of the remote switch to diagnose the DS1 
endpoint. 
6. If the MM710 connects to a line-side terminating device such as a 
PRI terminal adapter, contact the vendor of the line-side terminating 
device to diagnose the equipment.
1400
FAIL
Echo Canceller Function failed, this could be a hardware problem on the 
MM710:
1. Enter the busyout board command.
2. Enter the test board long command.
3. Enter the release board command.
4. If Test 138 still fails with EC 1400, replace the board.
1401
FAIL
Echo Canceller Function failed, this could be a hardware problem on the 
MM710:
1. Enter the busyout board command.
2. Enter the reset board command.
3. Enter the test board long command.
4. Enter the release board command.
5. If the test still fails replace the board.
 
PASS
DS1 signal is present and the physical link is healthy.
Table 592: TEST #138 Loss of Signal Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation
 3 of 4