Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1644 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
G250
,
G250-BRI
,
G350
See
on page 2539 for media module level
errors.
For individual port problems see the relevant MO:
For individual port problems see the relevant MO:
●
If the port is administered as a CO trunk, see
●
If the port is administered as a DID trunk, see
●
If the port is administered as a CAMA/E911 trunk, see
●
If the port is administered as an analog line port (station), see
●
If the port is administered as an external device alarm, see
●
If the port is administered as an analog endpoint, see
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the Integrated Analog Media Module (IAMM) has stopped functioning or is
physically removed from the system. This alarm is logged 11 minutes after removing the
Table 602: MG-IAMM Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
1 (
)
0
Sanity Failure
MIN
ON
18 (
0
busyout location
OFF
release location
23 (
)
WRN
OFF
257 (
65535
or Any
Control Channel Looparound
Test
MIN
ON
test board location
513 (
Any
None
MIN
ON
769 (
4358
None
-
-