Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1650 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
MG-ICC (Internal Call Controller)
S8700 | 8710
 / 
S8500
 / 
S8300
 / 
G700
This maintenance object monitors the H.323 link between the S8300 Media Server running as 
an LSP or as the primary call controller. It logs errors when the Keep Alive messages that are 
exchanged between the servers fail. These messages indicate the status of the H.323 link 
between the two. If the Keep Alive messages are active all is well; if not, an error is logged on 
the LSP only.
Error log entry and test to clear value
System Technician-Demanded Tests: Descriptions and Error 
Codes
There are no System Technician-Demanded Tests associated with this MO. 
MO Name in 
Alarm Log
Alarm
Level
Initial Command to Run
Full Name of MO
MG-ICC
MAJ
None
INTERNAL CALL CONTROLLER
Table 609: MG-ICC error log entries
Error
Type
Aux 
Data
Associated Test
Alarm
Level
On/Off 
Board
Test to Clear Value
1 None
MAJ
OFF
Error Type 1 indicates a failure of the H.323 link keep alive messages between the LSP 
and primary call controller. This is an indication that the LAN or the primary call controller is 
down.