Avaya 03-300430 User Manual
MMI-BD
Issue 1 June 2005
1661
Table 614: Test #6 TSI Crosstalk Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test, the traffic load on the
system is very high, or the time slots are out-of-service due to TDM-BUS
errors.
system is very high, or the time slots are out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present, or some tone detectors
are out-of-service.
oversized for the number of tone detectors present, or some tone detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
2000
ABRT
Response to the test was not received from the MMI-BD circuit pack within
the allowable time period.
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports are idle. Reset the circuit pack by issuing busyout board
location, reset board location, and release board
location.
location, reset board location, and release board
location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary resources to run this test. This is an
abnormal abort.
abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The TSI was found to be transmitting in error. This causes noisy and
unreliable connections.
unreliable connections.
1. Replace the circuit pack.
PASS
The TSI is correctly using its allocated time slots.