h. Error Types 3841 - 3844: are not related to VSP-MCU. They could be caused by network 
problems or from the customer endpoints. They are presented here for logging purposes 
only.
System Technician-Demanded Tests:
Descriptions and Error Codes
Resource Loop-Around Test (#1111)
This test is destructive.
This test checks the connectivity of the resource within MMI circuit pack and out to the TDM 
bus. The object is to test the circuitry that an H.221 bit stream comes in contact with when that 
stream is demultiplexed, pre-processed, written to the TDM bus and then reread (looped in the 
TSI), post-processed, multiplexed, and then written back to the TDM bus for verification. The 
video, audio, and data components of the bit stream are tested separately. If any one of these 
tests fails, the resource is taken out of service.
Code
Description
3841
CRC4 Error (Frame checksum error)
3842
Correctable BAS (Control msg bit error – 1- or 2-bit error, correctable)
3843
Uncorrectable BAS (Control msg bit error – 3-bit error or more, not 
correctable)
3844
Protocol Error (H.221 Protocol error from endpoint detected)
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
Resource Looparound test (#1111)
X
X
Destructive