Communication Manager Maintenance-Object Repair Procedures
1682 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 130: the circuit pack has been removed or has been insane for more than 21 
minutes. To clear the error, reinsert or replace the circuit pack.
Table 621: Modem Pool Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
Any
Any
Any
test port location sh r 1
18
0
busyout port 
location
WRN
OFF
release port location
130 (
)
None
WRN
ON
test port location sh
257
Conversion Resource 
Loop (#98)
MIN
ON
test port location s r 3
513
Modem Conference 
(#97)
MIN
ON
test port location l r 3
769
Modem NPE Crosstalk 
(#96)
MIN
ON
test port location l r 3