Avaya 03-300430 User Manual

Page of 2574
M/T-DIG (Maintenance/Test Digital Port)
Issue 1 June 2005
1719
 
1019
ABRT
An ISDN test call is in progress using this Maintenance/Test circuit pack. 
The Maintenance/Test circuit pack cannot perform a self-test on one of its 
digital ports while an ISDN test call is using either of the digital ports. Use 
list isdn-testcall to determine which call is using the port, from 
the M/T Port column. Wait for the test call to complete as indicated in the 
Start Time and Duration fields, or abort the test call with clear 
isdn-testcall grp#/mem#
, where grp#/mem# is determined from 
the B-channel field of list isdn-testcall.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1138
ABRT
This test does not run on port 3 of the Maintenance/Test circuit pack. This 
test will only run on port 2. Look at the results of the Digital Port Sanity 
test for port 2.
1. Run the command again for port 2 using test port location 
(02) or test port location (02) l.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
50
FAIL
The switch was unable to communicate with the port circuitry used for 
digital trunk testing.
100
FAIL
Data was not sent from port 2 to port 3 successfully in asynchronous 
mode.
1. Reset the circuit pack using busyout board locationreset 
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
Table 636: Test #565 Digital Port Sanity Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3