Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1734 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Did not receive a response from a circuit pack being used for the test 
within the allowable time period.
1. Reset the circuit pack (busyout board locationreset board 
location, and release board location).
2.  If the test fails again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2801
ABRT
No IP address defined.
1.  Verify IP interfaces translations and retest.
2802
ABRT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
2807
ABRT
The board is administered but not enabled in the change 
ipserver-interfaces screen.
1003
FAIL
Ping to the destination failed due to on-board problems of the source of 
the ping. The source of the ping can be a CLAN board or a IPMEDPRO 
board for this error to occur.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Look for problems associated with IPMEDPRO or CLAN boards in 
this region.
Table 642: Test #1417 Network Region Interconnectivity Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3