OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 June 2005
1737
 
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 15: this software audit error does not indicate a hardware malfunction. Run the 
short test sequence and investigate associated errors (if any).
c. Error Type 18: the DS1 OPS Line was busied out by busyout station ext. No calls 
can be made on this line.
d. Error Type 130: the circuit pack was removed or was insane for more than 11 minutes. To 
clear the error, reinsert or replace the circuit pack.
e. Error Type 1793 indicates a problem with the DS1 Interface circuit pack. Because there is 
no error against the OPS-LINE port, no alarm is raised against the OPS-LINE port. 
However, there should be errors logged against the DS1 Interface circuit pack. Look for 
DS1-BD/UDS1-BD errors in the Hardware Error Log, and follow the procedures in 
Table 643: DS1 OPS Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
)
0
Any
Any
Any
test station ext
)
Any
Audit and Update test 
(#36)
0
busyout station 
ext
WRN
OFF
release station ext
)
None
WRN
ON
test station ext
1281
Conference Circuit test 
(#7)
MIN
ON
test station ext l r 4
1537
NPE Crosstalk test (#6)
MIN
ON
test station ext l r 3
test board location l