Communication Manager Maintenance-Object Repair Procedures
1768 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1340
ABRT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test 
digital ports (ports 02 and 03 on the Maintenance/Test circuit pack) 
are present in the system. Because at least one Maintenance/Test 
circuit pack must always be present in the PN of S8700 
configurations, there should be at least two such ports present. If the 
ports are present, proceed to step 2. Otherwise, determine why no 
ports appear in the list config display. See 
2. Look for M/T-DIG errors in the Error Log. If present, se
3. If the ports are present and no errors are logged against them, retry 
the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit 
pack.
1392
ABRT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using display port where the 
display shows that the port is a TTI port, or list config, where the 
display shows a t for the port.
2. If list config or display port indicate that the port is not a TTI 
port, escalate the problem. If both commands indicate that the port is 
a TTI port, the abort is correct for the test, and no action is necessary.
2005
ABRT
The handshake between the Maintenance/Test digital port and the Data 
Module failed.
1. Look for M/T-DIG errors in the Error Log. If present, se
2. If test still aborts on retry, check physical connection of data module 
under test. Make sure the switches are on NORM, OFF (between 
REM_LP and LOC_LP), 9600, and ASYN.
3. If the test still aborts, replace the Data Module.
Table 654: Test #175 Data Module Internal Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation