PDMODULE (Processor Data Module)
Issue 1 June 2005
1771
 
2000
ABRT
Data module disconnected.
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring. Check for 
faulty wiring and faulty data module.
3. Retry the command at one-minute intervals a maximum of 5 times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit pack and 
repeat the test.
2500
ABRT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
3004
ABRT
ABRT
1. This error could be caused by the switch setting of the PDM. Verify 
that the switch on the PDM is set to the "remote loop" position. When 
the remote loop around test is completed, return the switch to the "off" 
position.
2. This error could be caused by the Network Control Data Channel. 
Look for DATA-CHL errors in the Hardware Error Log.
3. This error could also result if no data equipment is connected to the 
data module. Verify that (a) the data equipment is properly connected 
to the data module, (b) that power is available to the data equipment, 
and that (c) the data equipment is powered on.
4. This error could also occur if the baud rate of the data module is set 
to 19.2 Kbps since the Network Control circuit pack used by this test 
does not support baud rates greater than 9600 bps. Verify that the 
baud rate of the data module is set to 9600 bps or less.
1040
FAIL
Data received from remote loop back does not match data sent.
1. Check for faulty wiring.
2. Replace the data module and repeat the test.
3. If the test fails, replace the Digital Line circuit pack associated with 
the data module and repeat the test.
Table 654: Test #175 Data Module Internal Loop-Around Test  (continued)