Avaya 03-300430 User Manual
PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005
1777
OOS/FE
WRN
Far-end problems or
incompatibility
Check administration and status of
the corresponding port on the
terminal adapter.
WRN
The far-end port is busied out.
Check the status of the far-end
terminal adapter.
OOS/FE
PINS
Service message was sent and
the switch is waiting up to 2
minutes for a reply from the
far-end terminal adapter.
Wait 2 minutes, and check service
state after the PINS state has
cleared.
MTC/NE
System link demand busied out
Check link status. Release with
release link link#.
MTC/FE
WRN
Signaling channel has been
down for over 90 sec.
Consult ISDN-SGRP, ISDN-LNK
and/or SYS-LINK. Far-end terminal
adapter may currently be restarting.
WRN
Repeated failure of far end to
respond to messages.
Maintenance software will
periodically try to resend messages.
You can speed the process with
test port location (Test #256).
WRN
The far-end port is being tested.
Check status of the far-end terminal
adapter.
MTC/FE
PINS
Service message was sent, and
the switch is waiting up to 2
minutes for a reply from the
far-end terminal adapter.
Wait 2 minutes, and check service
state after the PINS state has
cleared.
INS
Normal operating state. ISDN
wideband calls are completing.
Table 655: PRI Endpoint Port Service States (continued)
Service
State
State
Alarm
Possible Cause
Possible Solution
2 of 2