PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005
1777
 
OOS/FE
WRN
Far-end problems or 
incompatibility
Check administration and status of 
the corresponding port on the 
terminal adapter.
WRN
The far-end port is busied out.
Check the status of the far-end 
terminal adapter.
OOS/FE 
PINS
Service message was sent and 
the switch is waiting up to 2 
minutes for a reply from the 
far-end terminal adapter.
Wait 2 minutes, and check service 
state after the PINS state has 
cleared.
MTC/NE
System link demand busied out
Check link status. Release with 
release link link#.
MTC/FE
WRN
Signaling channel has been 
down for over 90 sec.
Consult ISDN-SGRP, ISDN-LNK 
and/or SYS-LINK. Far-end terminal 
adapter may currently be restarting.
WRN
Repeated failure of far end to 
respond to messages.
Maintenance software will 
periodically try to resend messages. 
You can speed the process with 
test port location (Test #256).
WRN
The far-end port is being tested.
Check status of the far-end terminal 
adapter.
MTC/FE
PINS
Service message was sent, and 
the switch is waiting up to 2 
minutes for a reply from the 
far-end terminal adapter.
Wait 2 minutes, and check service 
state after the PINS state has 
cleared.
INS
Normal operating state. ISDN 
wideband calls are completing.
Table 655: PRI Endpoint Port Service States  (continued)
Service
State
Alarm
Possible Cause
Possible Solution
 2 of 2