Avaya 03-300430 User Manual

Page of 2574
PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005
1783
 
1004
ABRT
The port has been seized by a user for a valid call. Use status 
pri-endpoint extension
 to determine when the port is available for 
testing.
1. Retry the command at 1-minute intervals up to 5 times.
1117
ABRT
A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2020
ABRT
The test did not run due to an existing error on the specific port or a more 
general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit 
pack, and follow recommended procedures.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This will 
cause noisy and unreliable connections. The PE-BCHL is moved to 
out-of-service/near-end state.
1. Replace the circuit pack.
PASS
The port can communicate over the TDM bus.
Table 658: Test #6 NPE Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2