Communication Manager Maintenance-Object Repair Procedures
1786 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Signaling Link State Check Test (#255)
As noted in the preceding general description, operation of the PRI endpoint port depends on 
the health of the UDS1 interface circuit pack and System Link for proper operation. This test 
checks the status of those critical elements.
Service State Audit (#256)
As noted in the general description for PRI endpoint port, these ports may be in one of several 
service states as defined by the ISDN-PRI Specification. This test performs a service state audit 
with the far-end terminal adapter to ensure both sides agree on the service state.
A PASS for this test simply means that an audit message was successfully composed and sent 
out to the far-end terminal adapter. The ISDN Specification allows up to 2 minutes for a reply. If 
no reply is received within that 2-minute window, this switch will automatically try once again. If 
that attempt fails, an error will be logged (Error Type 3073) and the switch will then attempt 
recovery by automatically retrying approximately every 15 minutes. If the port was initially in the 
INS (in-service) state, it will now be placed in the MTC/FE (maintenance state, far-end problem) 
state. Until a Service State audit attempt is successful, no outgoing calls will be placed over this 
Table 661: Test #255 Signaling Link State Check Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1700
ABRT
Rollabout video abort. The PRI terminal adapter associated with this PRI 
endpoint extension is detached from the circuit pack. This is a normal 
abort when the rollabout video feature is enabled.
1. Either reconnect the disconnected PRI terminal adapter or disable the 
rollabout video feature on this circuit pack. To do the latter, enter 
change ds1 location and set the Alarm when PRI Endpoint 
Detached? field to y.
4
FAIL
There is a problem with the Signaling Channel and/or with the System 
Link.
1. Consult procedures for the ISDN-GRP and SYS-LINK. See also 
ISDN-LNK for useful information.
8
FAIL
There is a problem with the UDS1 interface circuit pack.
1. Consult procedures for UDS1-BD.
PASS
The signaling link hardware is OK.