Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1850 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Link Retry Test (#215)
This test sends a message to the journal printer management software process to make a data
call to the extension where the printer device connects to. If the journal printer link is already up,
this test passes without making any data call.
call to the extension where the printer device connects to. If the journal printer link is already up,
this test passes without making any data call.
FAIL
Internal System error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The link is torn down.
Table 679: Test #213 Link Tear Down Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2
Table 680: Test #215 Link Retry Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
10
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
20
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30
ABRT
Internal system error.
1. See
instructions.
1010
ABRT
The PMS Printer Link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log to release the
link from busyout state.
2. Retry test journal wakeup-log|pms-log l to execute the
test.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The link cannot be established.
1. See
instructions.
PASS
The link is up.