PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005
1903
 
PPP Link Status Inquiry Test (#1279)
This nondestructive test determines the state of the PPP link. The test passes only if the link is 
up.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
System software indicates at least one PPP link session is down (SOME 
UP).
1. Isolate downed sessions (status port location or status 
link n). 
Follow actions based on session information.
2
FAIL
System software indicates every PPP session is down (ALL DOWN).
1. Test the port (test port location) to verify the SCOTCH 
Synchronous Loop-around test (#1275) result.
2. If test passes, wait for system software to indicate ALL UP.
3. If the test fails, check the destination and other components in the 
path.
4. If the destination and other components in the path are in-service, 
take action based on session information.
PASS
Every session up.
Table 695: Test #1286 Session Status Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2
Table 696: Test #1279 PPP Link Status Inquiry Test 
Error
Code
Test
Result
Description / Recommendation
1124
ABRT
ppp link is not enabled.
1. Verify that the ppp link is enabled (status port location
status link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.