Avaya 03-300430 User Manual

Page of 2574
PPP-PT (Control LAN Packet/Port)
Issue 1 June 2005
1901
 
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1003
FAIL
Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board 
locationreset board location, and release board 
location
).
3. If the problem persists, re-administer the PPP connection through a 
different PPP port, if available.
4. If the problem still persists, or if there are no other available PPP 
ports, replace the circuit pack.
1007
FAIL
Ping to the destination failed due to the destination down.
1. A PPP destination or a component in the path (e.g., DS1 trunk) may 
be down. Check the status of the destination or other components in 
the path.
2. If the destination and every component in the path is in-service, ping 
the PPP destinations (ping ip-address xxx.xxx.xxx.xxx).
PASS
TCP/IP Ping test (#1281) is successful.
Table 694: Test #1281 TCP/IP Ping Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2