Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1934 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Digital Line Electronic Power Feed/Positive
Temperature Coefficient/PPF Test (#11)
This is an Electronic Power Feed (EPF) restoration test. In this test, the processor requests that 
the EPF be turned on for a given port, and an attempt is made to turn on the power supply to the 
station. If no current is drawn, the station is probably not connected. If an overcurrent condition 
is sensed, there may be a short in the loop. A message is returned reporting that either the EPF 
was successfully turned on, or that an overcurrent condition was sensed. This test is repeated 
again 5 seconds later.
Table 710: Test #11 Digital Line Electronic Power Feed Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call. 
1. Enter display port WRN to determine the station extension or 
attendant number of the port. 
2. Use status station or status attendant to determine the 
service state of the port. 
If the port is in use, wait until the port is idle before testing. 
Attendants are always in use (off-hook) if the handset is plugged in 
and the port is not busied out.
If the port status is idle, then retry the command at 1-minute 
intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2