Avaya 03-300430 User Manual

Page of 2574
SIP-SGRP (SIP Signaling Group)
Issue 1 June 2005
1971
 
Notes:
a. Error Type 0: 
Run the short test sequence first. If every test passes, run the long test sequence. Refer to 
each appropriate test’s description, and follow its recommended procedures.
b. Error Type 1: Represents a failure of the C-LAN hardware (IP-PROCR in S8300 systems) 
carrying the signaling group channel. 
To determine which C-LAN had been administered for this signaling group, find the 
near-end node name on the signaling group form; then find the C-LAN or IP-PROCR 
with the same node name on the ip-interfaces form.
Check for errors against the CLAN-BD MO.
c. Error Type 18: Logged when the signaling group in question is busied out by Craft. Make 
sure, if appropriate, that the signaling group is released from busy using the release 
signaling-group grp#
 command.
d. Error Type 257: Tracks failures of the SIP signaling-group PING test. SIP signaling-group 
PING test failures are documented later in this MO.
e. Error Type 513: Tracks excessive round-trip delay of the SIP signaling-group PING test, if 
the round-trip delay exceeds 4 seconds.
f. Error Type: 770: Tracks excessive latency and packet-loss from background IP 
measurements collected by the Media Processor Board. Indicates that test packets sent 
from a media processor circuit pack to the far-end ip address specified on the 
signaling-group form have exceeded the IP latency and loss thresholds, as 
administered on the system-parameters ip-options form. Exceeding these 
thresholds indicates that the IP network may not be providing sufficient quality of service for 
adequate transmission of voice. If the signaling group has been administered to enable 
BYPASS, then error type 1025 also occurs. 
1281 (
)
Any
MEDPRO Status test (#1392)
MIN
OFF
1537 (
)
Any
MEDPRO Status test (#1392
MIN
OFF
1794 (
)
MEDPRO Status test (#1392)
MIN
OFF
test signaling-group grp#
2561 (
Any
Registered to LSP Inline Error
MIN
OFF
3073 (
)
19
Far-end TLS Certificate Failure 
Inline Error
MIN OFF
3329 (
21
Near-end TLS Certificate failure 
Inline Error
MIN OFF
Table 721: SIP-SGRP Signaling Group Error Log Entries  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2