Avaya 03-300430 User Manual

Page of 2574
SIP-SGRP (SIP Signaling Group)
Issue 1 June 2005
1973
 
System Technician-Demanded Tests:
Descriptions and Error Codes
Always Investigate tests in the order presented in the table below when inspecting errors in the 
system. For example, by clearing error codes associated with the CLAN Ethernet Status test 
(#1386), you may also clear errors generated from other tests in the testing sequence.
CLAN Ethernet Status Test (#1386)
This test is nondestructive.
This test checks the status of the C-LAN Ethernet port that is the near end gatekeeper for this 
signaling group. If the C-LAN Ethernet port is in service, the test passes; if it is OOS (out of 
service), the test fails.
Note:
Note:
Failure of this test will put the SIG-GRP in the OOS state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
CLAN Ethernet Status test (#1386)
X
X
ND
MedPro Status test (#1392)
X
X
ND
SIP Signaling Group Ping test (#1387)
X
X
ND
Table 722: Test #1386 CLAN Ethernet Status Test 
Error
Code
Test
Result
Description / Recommendation
1125
ABRT
Ethernet Link is not in service.
1. Check if the Ethernet link is in service or not. If the link is not in service, 
release the link using release link n or release port 
location
, and repeat the test. This is a normal abort.
2. If the test continues to abort after following the repair procedures, 
escalate the problem.
 1 of 2