ABRT
Response to the test was not received from the C-LAN circuit pack within 
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the 
other ports on the board are idle (amber LED is off). Reset the circuit 
pack by issuing busyout board locationreset board 
location
, and release board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
The necessary system resources to execute the test could not be 
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3times.
2800
ABRT
No C-LAN in the same region.
1. Verify translations and retest.
2801
ABRT
No IP address defined.
1. Verify translations and retest.
2802
ABRT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
89 
1007
FAIL
PING to the destination failed through this port because the destination 
was down.
1. Verify that at least one destination reachable through this port is “up”. 
Once verified, execute test signaling-group grp# to verify that 
the SIP Signaling Group Ping test (#1387) passes.
PASS
PING through this port was successful.
Table 723: Test #1387 SIP Signaling Group Ping Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2