Avaya 03-300430 User Manual

Page of 2574
SIP-SGRP (SIP Signaling Group)
Issue 1 June 2005
1977
 
MedPro Status Test (#1392)
This test is nondestructive.
This test determines if at least one media processor port exists that is in service, and that 
serves the same region as the C-LAN that the signaling group uses. If at least one exists and is 
in service, the test passes; otherwise, the test fails.
Table 724: Test #1392 MedPro Status Test 
Error
Code
Test
Result
Description / Recommendation
2100
ABRT
The necessary system resources to execute the test could not be 
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
Any
ABRT
Internal system Error.
1. Retry the command at 1-minute intervals up to 3 times
FAIL
No MEDPRO ports in this region are in service. Every session is down.
1. Check the system for errors against MEDPRO and MEDPROPT 
maintenance objects.
2. Execute test signaling-group grp# and verify the result of the 
SIP Signaling Group Ping test (#1387). If the test continues to fail, 
escalate the problem. If the test passes, wait for the sessions to come 
up.
PASS
Every session on the Ethernet link is up.