Communication Manager Maintenance-Object Repair Procedures
2032 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2303
ABRT
The SNC circuit pack responded that the software test requested is not
valid.
valid.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABRT
SNC firmware is not able to run the test.
1. Retry the command at 1-minute intervals up to 3 times.
2306
ABRT
The SNC circuit pack is not responding to test requests sent by software.
1. Run test led switch-node for the switch node where this board
resides to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on
this board do not light, run test 760 using test board location l
for the active SNC in this carrier. Wait 5 minutes and then try step 1
one more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNC may be service interrupting. See
one more time. If the LEDs on this board still do not light, replace this
board. Replacing an SNC may be service interrupting. See
on page 2000 for the procedure for
replacing an SNC.
3. If none of the LEDs light for the boards in the same carrier as this
board, fix any problems associated with the connectivity of this carrier
to the server.
to the server.
a. Use list fiber-link to obtain a list of the fiber connections to
this carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
Table 742: TEST #778 SNC On-Board Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3