Communication Manager Maintenance-Object Repair Procedures
2054 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
If this procedure is run on both endpoints on a fiber link (Expansion Interface circuit packs or 
Switch Node Interface circuit packs), and both check out fine, then the failure is most likely 
in the connection (fiber or metallic) itself if neither endpoint circuit pack is busied out, but the 
link remains inactive.
1. Use busyout board location to busyout the circuit pack (Expansion Interface or 
SNI).
2. Disconnect the transmit and receive fiber pair from the lightwave transceiver on the back 
of the circuit pack (Expansion Interface or Switch Node Interface) slot.
Note:
Note:
Note which is the transmit fiber and which is the receive fiber for proper 
re-connection at the end of this procedure. The fiber connected to the transmit 
side of the lightwave transceiver on one circuit pack should be connected to the 
receive side of the lightwave transceiver on the circuit pack on the opposite end 
of the fiber.
3. Using a spare fiber jumper cable, interconnect the transmit and receive jacks of the 
lightwave transceiver as shown in 
Note:
Note:
Make sure that the total length of the fiber jumper cable does not exceed the 
maximum length recommended for the fiber link connections between cabinets. 
Test the Expansion Interface or SNI circuit pack within connectivity guidelines so 
that test results are not influenced due to improper cable length.
4. Go to the front of the cabinet and inspect the yellow LED.
If the yellow LED flashes on at a rate of once per second, the Expansion Interface or 
Switch Node Interface circuit pack or transceiver should be replaced.
If the yellow LED flashes on at a rate of five times per second, the circuit pack 
(Expansion Interface or Switch Node Interface) or the lightwave transceiver may need 
replacement. This may also be due to a faulty system clock on the network containing 
the Expansion Interface circuit pack or in the switch node carrier containing the SNI.
If the yellow LED was blinking before starting this procedure and the yellow LED is not 
blinking now, this circuit pack (Expansion Interface or Switch Node Interface) and the 
lightwave transceiver are functioning properly.
5. Replace faulty component(s) and reconnect the original fiber. Be sure to reconnect the 
fibers properly as noted in Step 2.
6. Use release board location to release the Expansion Interface circuit pack or 
Switch Node Interface circuit pack.